Each battery is fitted with an internal battery management system to provide safe charging and discharging at all times. This system provides internal short circuit, over temperature and under/over voltage cut off. Can be wired in series and/or parallel.
5 Year Warranty
This 12V 150Ah LiFePO4 replacement battery is compatible in size with traditional 150Ah SLA batteries, but with all the benefits of cutting edge lithium technology. LiFePO4 batteries offer longer service life than traditional lead acid batteries, plus weigh less than HALF as much as SLA batteries. LiFePO4 also provide more usable life per cycle, allowing for longer run times by holding a higher voltage until capacity is almost exhausted. This will replace 300amps of AGM battery.
These batteries will also maintain 80-90% charge when in storage - far higher than their lead acid counterparts. The latest generation in maintenance free batteries is here!
Dimensions: 521 x 237 x 217mm
Overall Weight: 20kg
Terminal Type: M8 / F12
Connection: 12-48V max 4 in series, no limit in parallel.
Note: When used in series each battery will need to be discharged to cut off before connecting so that all cells are all balanced.
- Case Material: ABS
- Case IP Rating: IP56
- Cell Type: Prismatic
- Certification: CB/CE, UN38.3, UL1642 @ cell.
- Shipping Class: UN3480, Class 9
- Battery Module Specification
- Nominal Voltage: 12.8V @ 25°C, 0.2C
- Capacity: 150Ah @ 25°C, 0.2C
Operating Parameters
- Charging Voltage: 13.8 - 14.4V
- Discharging Voltage: 9.2V-15.4V (Recommended 11.8V)
- Charging Current: 150A max (Recommended 50A)
- Max Constant Discharge: 150A
- Pulse Discharge: 1300A for 50mS
Temperature
- Charge Range: 0 to 45°C
- Discharge Range: -20 to 60°C
- Storage Range: -20 to 45°C
Design Life:
- >10 years @ 25°C, 0.2C
- Cycle Life (25°C, 0.2C): >2000 times (100% DOD to 80% end)
- Cycle Life (25°C, 0.5C): >4000 cycles (100% DOD to 50% end)
BMS Parameters
- Charging
- Cell Voltage Protection: 3.9V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38V or module voltage <13.52V)
- Module Voltage Protection: 15.6V Delay 1-2S (Recover when discharge current >1A or cell voltage <3.38V or module voltage <13.52V)
- Over Charging Current 1: 150A Delay 20-30S (Turn to pre-charge mode and try to recover in every 3 minutes)
- Temperature Protection: <-10°C or >70°C, Delay 1-2S (Recovery when >0°C or <60°C)
Discharging
- Cell Voltage Protection: 2.2V Delay 500mS (Recover when charge current >1A or cell voltage >2.6V or module voltage >10.4V)
- Module Voltage Protection: 8.8V Delay 1-2S (Recover when charge current >1A or cell voltage >2.95V or module voltage >11.8V)
- Over Discharging Current 1: 550-650A Delay 500-1500mS (Recover when charging current >1A, or recover in every 60S)
- Over Discharging Current 2: 1100-1300A Delay 50-150mS (Recover when charging current >1A, or recover in every 60S)
- Short Circuit: 200-700us
- Temperature Protection: <-20°C or >75°C, Delay 1-2S (Recovery when >-10°C or <65°C)
BMS Features
- PCB Temp Protection: >115°C Delay 1-2S Recover when <80°C
- Cell Balance: 25-45mA passive balance cell voltage difference > 45mV
- Temperature Accuracy: ±2°C Cycle measurement Measuring range -40 to 100°C
- Voltage Accuracy: ±20mV Cycle measurement for cells and modules
- Current Accuracy: FSC±5% Cycle measurement measuring range -200 to +200
- SOC: 5% (integral calculation)
- Power Consumption: <300uA (switch off mode - storage), <100uA (sleep mode - protection & standby), <15mA (operating mode)